|
MetaMorph Inc
linescan metamorph Linescan Metamorph, supplied by MetaMorph Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/linescan+tool+of+the+metamorph+imaging+software/10__1074_slash_jbc__m111__227678-52-12-13?v=MetaMorph+Inc Average 90 stars, based on 1 article reviews
linescan metamorph - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
MetaMorph Inc
kymograph images ![]() Kymograph Images, supplied by MetaMorph Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/linescan+tool+of+the+metamorph+imaging+software/pmc03708452-125-29-59?v=MetaMorph+Inc Average 90 stars, based on 1 article reviews
kymograph images - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
universal imaging inc
metamorph 6.1 software ![]() Metamorph 6.1 Software, supplied by universal imaging inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/linescan+tool+of+the+metamorph+imaging+software/pmc03579524-219-8-10?v=universal+imaging+inc Average 90 stars, based on 1 article reviews
metamorph 6.1 software - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
MetaMorph Inc
metamorph software ![]() Metamorph Software, supplied by MetaMorph Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/linescan+tool+of+the+metamorph+imaging+software/pmc03795341-317-0-7?v=MetaMorph+Inc Average 90 stars, based on 1 article reviews
metamorph software - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
MetaMorph Inc
linescan kymograph images ![]() Linescan Kymograph Images, supplied by MetaMorph Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/linescan+tool+of+the+metamorph+imaging+software/pmc05591308-95-0-45?v=MetaMorph+Inc Average 90 stars, based on 1 article reviews
linescan kymograph images - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
MetaMorph Inc
linescan tool ![]() Linescan Tool, supplied by MetaMorph Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/linescan+tool+of+the+metamorph+imaging+software/pmc03816481-333-10-13?v=MetaMorph+Inc Average 90 stars, based on 1 article reviews
linescan tool - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
MetaMorph Inc
linescan application ![]() Linescan Application, supplied by MetaMorph Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/linescan+tool+of+the+metamorph+imaging+software/10__1091_slash_mbc__e20___06___0356-304-6-9?v=MetaMorph+Inc Average 90 stars, based on 1 article reviews
linescan application - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
MetaMorph Inc
linescans of the fluorescence intensities ![]() Linescans Of The Fluorescence Intensities, supplied by MetaMorph Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/linescan+tool+of+the+metamorph+imaging+software/pmc03135479__E11___01___0052_1-9-0-11?v=MetaMorph+Inc Average 90 stars, based on 1 article reviews
linescans of the fluorescence intensities - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
MetaMorph Inc
linescans ![]() Linescans, supplied by MetaMorph Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/linescan+tool+of+the+metamorph+imaging+software/pmc02902237-163-24-25?v=MetaMorph+Inc Average 90 stars, based on 1 article reviews
linescans - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
MetaMorph Inc
linescan function of metamorph 3.0 ![]() Linescan Function Of Metamorph 3.0, supplied by MetaMorph Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/linescan+tool+of+the+metamorph+imaging+software/pm10491266-131-14-14?v=MetaMorph+Inc Average 90 stars, based on 1 article reviews
linescan function of metamorph 3.0 - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
MetaMorph Inc
metamorph offline 7.1.7.0 ![]() Metamorph Offline 7.1.7.0, supplied by MetaMorph Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/linescan+tool+of+the+metamorph+imaging+software/pmc02744908-228-13-13?v=MetaMorph+Inc Average 90 stars, based on 1 article reviews
metamorph offline 7.1.7.0 - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
MetaMorph Inc
imaging software ![]() Imaging Software, supplied by MetaMorph Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/linescan+tool+of+the+metamorph+imaging+software/pmc03651793-103-1-1?v=MetaMorph+Inc Average 90 stars, based on 1 article reviews
imaging software - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
Image Search Results
Journal: The Journal of neuroscience : the official journal of the Society for Neuroscience
Article Title: Cytotoxicity of intracellular A?42 amyloid oligomers involves Ca 2+ release from the ER by stimulated production of inositol trisphosphate
doi: 10.1523/JNEUROSCI.4367-12.2013
Figure Lengend Snippet: Intracellular injection of Aβ42 oligomers into Xenopus oocytes evokes increases in cytosolic [Ca2+]. A, Overview of the experimental system, constructed around an Olympus IX71 inverted microscope. Fluorescence excited in the specimen by the 488 nm laser beam was collected through the objective lens and imaged by a Photometrics Cascade 128± camera. An oocyte loaded with fluo-4 dextran, was positioned animal hemisphere down in to a coverglass forming the base of the imaging chamber. A two-electrode voltage clamp allowed the membrane potential to be stepped to strongly negative potentials to enhance Ca2+ influx through the plasma membrane. Microinjection into oocytes was performed using a Drummond nanoinjector mounted on a hydraulic micromanipulator. A glass pipette filled with Aβ42 solution was inserted vertically down through the entire oocyte to a pre-established position, with the tip positioned a few µm inward from the plasma membrane and centered within the image field. B, Aβ42 oligomers, but not monomers, evoke cytosolic Ca2+ signals. The traces represent the mean time course of Ca2+-dependent fluorescence recorded from oocytes injected with 10 nl of Aβ42 monomer (red trace; n= 3 oocytes) or oligomers (black trace; n = 6 oocytes), both at a concentration of 1 µg ml−1). The arrow indicates the time of Aβ injection. Measurements were obtained as the average fluorescence throughout the imaged field, and are plotted as the ratio of fluorescence changes at any given time (ΔF) over the mean fluorescence before injection (Fo). C, D, E, Linescan (kymograph) images illustrating different spatio-temporal patterns of fluorescence Ca2+ signals evoked by Aβ42 oligomer injections. Panels depict fluorescence measured along a line on the video record as the y-axis, with time running left to right along the x-axis. Increasing fluo-4 pseudo-ratio signals (increasing free [Ca2+]) are represented by warmer colors as depicted by the color bar and by increasing height of each pixel. The trace(s) above each panel show fluorescence signals monitored from small regions along the linescan, positioned as marked by the horizontal arrow(s). The timescales of these traces are the same as the calibration bar for the linescan images, and the amplitudes of the fluorescence ratio changes (F/Fo) correspond to the heights of the color bars. Aβ42 oligomers were injected 1s after the beginning of the record in C. Records in (D) and (E) were obtained beginning 2–5 min after injection of Aβ42 oligomers. F, Corresponding linescan image and fluorescence traces recorded in response to injection of 10 nl of 100 pM IP3. The injection was delivered about 2.5 s before the beginning of the record. Responses are representative of records in 5 oocytes. G, Traces of average fluorescence ratio changes (ΔF/Fo) from ∼20 × 20 µm regions of interest in individual oocytes, showing Ca2+ signals evoked by 10 nl injections of Aβ42 oligomers at concentrations of 3, 10 and 30 µg ml−1, as indicated. Responses are representative, respectively, of records in 4, 4 and 5 oocytes.
Article Snippet: Spatio-temporal patterns of Ca 2+ signals evoked by intracellular Aβ42 oligomers and IP 3 Aβ42 oligomer injections evoked distinct spatio-temporal patterns of Ca 2+ signals, as illustrated in as
Techniques: Injection, Construct, Inverted Microscopy, Fluorescence, Imaging, Membrane, Clinical Proteomics, Microinjection, Transferring, Concentration Assay
Journal: Scientific Reports
Article Title: Lattice light sheet imaging of membrane nanotubes between human breast cancer cells in culture and in brain metastases
doi: 10.1038/s41598-017-11223-y
Figure Lengend Snippet: Membrane nanotubes form connections between MDA-231 cells in culture. ( a , b ) Representative lattice light-sheet image of MDA-231 cells visualized by a GFP-tagged membrane marker, illustrating nanotubes interconnecting with other MDA-231 cells and contacting the coverglass. See also Movie . ( a ) is a maximum intensity z-projection (top view) of the imaging volume, and ( b ) shows an orthogonal (side) view of the same volume. ( c , d ) Histograms plot the distributions of lengths of nanotubes that interconnect MDA-231 cells ( c , n = 98 nanotubes from 16 imaging fields) and those that contact the cover glass ( d ) 113 nanotubes). Insets in ( c , d ) are transverse linescan profiles showing the widths of nanotubes that interconnect MDA-231 cells (n = 6, mean FWHM 466 ± 31 nm) and those that contact the coverglass (n = 6, mean FWHM 423 ± 15 nm).
Article Snippet:
Techniques: Membrane, Marker, Imaging